Product Description
These replacement parts fit the Matala VersiFlow Pump series. How to know which parts to replace:
If your direct drive pump breaks the GFI on our outdoor receptacle but does not make noise and runs when plugged into a non-GFI outlet, you probably need a rebuild kit. Fresh oil, gaskets, and O-rings may fix your pump. This is true in most cases.
If your direct drive pump whirs or hesitates but will start when you help start the impeller spinning manually, your pump probably needs a capacitor.
If your direct drive pump makes a grinding sound, it probably needs new bearings.